About Zhaolin Plaza

Zhaolin Plaza is a premier commercial complex located in the core business district of the Beijing Economic-Technological Development Area. The plaza consists of two office buildings, Building A and Building B, with a total construction area of 138,000 square meters.

Each building rises 25 floors above ground with 3 underground levels, reaching a height of 108.6 meters. These modern office towers house numerous businesses and require reliable, efficient HVAC systems to maintain comfort for thousands of occupants. The central air-conditioning circulating water systems are critical infrastructure, and protecting them from scale and corrosion is essential for operational efficiency and equipment longevity.

138k

m² Total Area

25

Floors Each

2

Vulcan S500 Units

Zhaolin Plaza mineral descaler hard water

The Challenge: Chemical Treatment & Water Waste

The central air-conditioning systems in both buildings faced common but costly challenges:

  • Chemical Dependence: Reliance on chemical scale and corrosion inhibitors, requiring ongoing purchases and handling.
  • Water Waste: Frequent blow-down was needed to manage conductivity and hardness, wasting water.
  • Scale Formation: Existing scale on cooling tower packing was reducing heat transfer efficiency.
  • Limited Concentration Ratio: Inability to safely concentrate circulating water increased makeup water demand.

Installation Details

Location

Complex: Zhaolin Plaza

Area: Beijing Economic-Technological Development Area

Buildings: Building A & Building B

Country: China

Vulcan Installation

Model: Vulcan S500 (one per building)

System: Central air-conditioning circulating water

Make-up Water: 270 µS/cm conductivity

Installed by: Beijing Vulcan Water

Installation Gallery

Cooling tower and piping at Zhaolin Plaza

Cooling tower circulating water system

Zhaolin Plaza Building A and B eterior

Zhaolin Plaza office towers (108.6m)

Quantifiable Results: Water Quality Evolution

The make-up water entering the system had a conductivity of 270 µS/cm. The following data was recorded after Vulcan installation, with no water blow-down during the test period:

ParameterAt 2 MonthsAt 5 MonthsChange
Conductivity 3,680 µS/cm 6,630 µS/cm +80% (stable operation)
Total Hardness 672 mg/L 2,250 mg/L No scaling at high concentration
Total Alkalinity 298 mg/L 346 mg/L Minimal increase
Calcium 204 mg/L 346 mg/L Remained in solution
Concentration Ratio

20x

Achieved without blow-down, compared to typical 3-5x with chemical treatment.

Key Outcomes
  • Chemical inhibitors completely replaced
  • Scale fell off cooling tower packing
  • No new scale formation observed
  • Approaching temperature remained stable

Benefits for Commercial Office Buildings

Water Conservation

Significantly reduces blow-down and wastewater

Chemical-Free

Eliminates scale inhibitor purchases

HVAC Efficiency

Stable approaching temperature, less energy

High Concentration

20x ratio without scaling

Technical Specifications: Vulcan S500

Vulcan S500 Specifications
Max Pipe Diameter: 20 inches (500 mm)
Max Flow Rate: 2,600 GPM (600 m³/h)
Power Consumption: 25 - 35 W
Connection: Non-invasive (wraps around pipe)
Maintenance: Zero

*Login for pricing and exact specifications.

Redefining What's Possible in Cooling Water Treatment

The Zhaolin Plaza case study shatters conventional limitations of cooling water treatment. With Vulcan S500 units, two 108-meter office towers operated their HVAC systems at a 20x concentration ratio—far beyond the 3-5x typical with chemicals—without a single blow-down. Conductivity reached 6,630 µS/cm, hardness hit 2,250 mg/L, and yet the system remained stable, scale fell away, and chemical inhibitors were completely eliminated. This is the future of sustainable building operations: chemical-free, water-conserving, and maintenance-free.

Related Commercial Building Case Studies

Duo Towers Paris
Duo Towers Paris

Twin skyscrapers protect main water lines with S25 & S50.

Read More
Taikang Financial Tower
Taikang Financial Tower

4 heat exchanger systems protected without interruption.

Read More
Marina Plaza Dubai
Marina Plaza Dubai

Grade A office building protects cooling tower operations.

Read More

Optimize Your Building's Cooling System

Join Zhaolin Plaza and other commercial leaders in choosing Vulcan for chemical-free, water-conserving scale prevention.

About the Author

Waslix (Vulcan Mineral Descaler) provides non-chemical, maintenance-free scale prevention using impulse technology. This case study documents the installation of two Vulcan S500 units at Zhaolin Plaza office buildings in Beijing, China, achieving 20x concentration ratio and eliminating chemical inhibitors.